|
Photomedicine and Laser Surgery
Bond Strength of Self-Etching Primer to Bur Cut, Er,Cr:YSGG, and Er:YAG Lased Dental Surfaces
To cite this article:
Marcella Esteves-Oliveira, Denise M. Zezell, Christian Apel, Miriam L. Turbino, Ana Cecília Corrêa Aranha, Carlos de Paula Eduardo, Norbert Gutknecht.
Photomedicine and Laser Surgery.
October 2007,
25(5): 373-380.
doi:10.1089/pho.2007.2044.
Marcella Esteves-Oliveira, M.Sc.Department for Conservative Dentistry, Periodontology and Preventive Dentistry (ZPP), RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany Denise M. Zezell, Ph.D.Centro de Lasers e Applicações (CLA), Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN), Av Prof. Lineu Prestes 2242, São Paulo, Brazil. Christian Apel, D.D.S., Ph.D.Department for Conservative Dentistry, Periodontology and Preventive Dentistry (ZPP), RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany Miriam L. Turbino, Ph.D.Restorative Dentistry Department, Dentistry School of University of São Paulo (USP), Av. Prof. Lineu Prestes 2227, São Paulo, Brazil. Ana Cecília Corrêa Aranha, Ph.D.Restorative Dentistry Department, Dentistry School of University of São Paulo (USP), Av. Prof. Lineu Prestes 2227, São Paulo, Brazil. Carlos de Paula Eduardo, Ph.D.Restorative Dentistry Department, Dentistry School of University of São Paulo (USP), Av. Prof. Lineu Prestes 2227, São Paulo, Brazil. Norbert Gutknecht, Ph.D.Department for Conservative Dentistry, Periodontology and Preventive Dentistry (ZPP), RWTH Aachen University, Pauwelsstr. 30, Aachen, Germany Objective: The purpose of this study was to evaluate the tensile bond strength of a self-etching primer system to enamel and dentin surfaces treated with Er:YAG and Er,Cr:YSGG lasers. Background Data: The recently introduced self-etching primer systems have been shown to adhere better to dental surfaces with thin or no smear layers. Moreover, there have been no previous reports on the bond strength of these adhesives to Er,Cr:YSGG laser-irradiated enamel and dentin, which have been shown to be free of a smear layer. Methods: Thirty samples of enamel and thirty of dentin were divided into three groups. The first group of each substrate served as a control with a standardized bur cut, and the other two groups were conditioned with Er:YAG (350 mJ, 10 Hz, 20 J/cm2 for enamel; 300 mJ, 6 Hz, 17 J/cm2 for dentin) and Er,Cr:YSGG laser (125 mJ, 20 Hz, 16 J/cm2 for both substrates). After the bonding procedure, samples were restored with composite resin, and the tensile bond strength test was performed. Results: The ANOVA two-way analysis and the Tukey test at 5% significance level showed that for enamel and dentin, the bond strength values were statistically higher in Er:YAG-laser treated than in Er,Cr:YSGG-laser treated surfaces (p = 0.0001). However, bond strength means for both laser-irradiated groups were statistically lower than for the bur cut group (Er:YAG: p = 0.0281 and Er,Cr:YSGG: p < 0.0001). SEM observation of laser-irradiated surfaces revealed a roughened aspect and absence of smear layer. Conclusions: The self-etching system adhesion was influenced by the type of erbium laser used, and the bond strength was higher in the Er:YAG-laser irradiated than in the Er,Cr:YSGG-laser irradiated surfaces.  This paper was cited by:Effects of erbium:yttrium–aluminum–garnet and neodymium:yttrium–aluminum–garnet laser hypersensitivity treatment parameters on the bond strength of self-etch adhesives E. Yazıcı, S. Gurgan, N. Gutknecht, S. Imazato Lasers in Medical Science. Jun 2009 CrossRef Evaluation of the Surface Roughness and Morphologic Features of Y-TZP Ceramics after Different Surface Treatments Andrea N. Cavalcanti, Peter Pilecki, Richard Mark Foxton, Timothy F. Watson, Marcelo Tavares Oliveira, Marcelo Gianinni, Giselle M. Marchi Photomedicine and Laser Surgery. Jun 2009, Vol. 27, No. 3: 473-479 Abstract | Full Text PDF | Reprints & PermissionsMicroleakage of Class V Cavities with Different Adhesive Systems Prepared by a Diamond Instrument and Different Parameters of Er:YAG Laser Irradiation Nuray Attar, Yonca Korkmaz, Emre Ozel, Ceren Ozge Bicer, Erhan Firatli Photomedicine and Laser Surgery. Dec 2008, Vol. 26, No. 6: 585-591 Abstract | Full Text PDF | Reprints & PermissionsInfluence of the additional Er:YAG laser conditioning step on the microleakage of class V restorations Marcella Esteves-Oliveira, Wendell L. Carvalho, Carlos de P. Eduardo, Denise M. Zezell Journal of Biomedical Materials Research Part B: Applied Biomaterials. Dec 2008, Vol. 87B, No. 2: 538-543 CrossRef Shear Bond Strength of Composite Bonded to Er,Cr:YSGG Laser-Prepared Dentin Sevil Gurgan, Arlin Kiremitci, Filiz Yalcin Cakir, Jale Gorucu, Tugba Alpaslan, Esra Yazici, Norbert Gutknecht Photomedicine and Laser Surgery. Oct 2008, Vol. 26, No. 5: 495-500 Abstract | Full Text PDF | Reprints & PermissionsAdhesives bonded to erbium:yttrium–aluminum–garnet laser-irradiated dentin: transmission electron microscopy, scanning electron microscopy and tensile bond strength analyses Andreia Cristina Bastos Ramos, Marcella Esteves-Oliveira, Victor E. Arana-Chavez, Carlos Paula Eduardo Lasers in Medical Science. Sep 2008 CrossRef
|
|