Hello. Sign in to personalize your visit. New user? Register now.  
Photomedicine and Laser Surgery
The Influence of Er:YAG Laser Conditioning versus Self-Etching Adhesives with Acid Etching on the Shear Bond Strength of Orthodontic Brackets

To cite this article:
Aylin Gokcelik, Yonca Ozel, Emre Ozel, Neslihan Arhun, Nuray Attar, Sonmez Firatli, Erhan Firatli. Photomedicine and Laser Surgery. December 2007, 25(6): 508-512. doi:10.1089/pho.2007.2096.

Full Text: • PDF for printing (91.7 KB) • PDF w/ links (136.5 KB)


Aylin Gokcelik, D.D.S., Ph.D.
Department of Orthodontics, Faculty of Dentistry, Baskent University, Ankara, Turkey.
Yonca Ozel, D.D.S., Ph.D.
Department of Conservative Dentistry, Faculty of Dentistry, Baskent University, Ankara, Turkey.
Emre Ozel, D.D.S., M.Sc., Ph.D.
Department of Conservative Dentistry, Faculty of Dentistry, Baskent University, Ankara, Turkey.
Neslihan Arhun, D.D.S., M.Sc., Ph.D.
Department of Conservative Dentistry, Faculty of Dentistry, Baskent University, Ankara, Turkey.
Nuray Attar, D.D.S., Ph.D.
Department of Conservative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey.
Sonmez Firatli, D.D.S., Ph.D.
Department of Orthodontics, School of Dentistry, University of Istanbul, Istanbul, Turkey.
Erhan Firatli, D.D.S., Ph.D.
Department of Periodontology, School of Dentistry, University of Istanbul, Istanbul, Turkey.

Objective: The aim of this study was to compare the shear bond strength (SBS) of orthodontic brackets after acid etching, laser ablation, self-etching primer application, and combined treatments. Methods: One hundred defect-free premolars were randomly assigned to five groups. The teeth received the following treatments: group 1: phosphoric acid + Transbond XT primer; group 2: Transbond Plus Self-Etching Primer (TPSEP); group 3: Er:YAG laser ablation + Transbond XT primer; group 4: Er:YAG laser ablation + phosphoric acid + Transbond XT primer; and group 5: Er:YAG laser ablation + TPSEP. Transbond XT Adhesive Paste was used in all groups for bracket bonding. Samples were stored in deionized water at 37°C for 24 h. The shear debonding test was performed at a crosshead speed of 5 mm/min. Failed brackets were examined by a stereomicroscope at 16 × magnification to determine the bond failure interface using a modified adhesive remnant index (ARI). SBS values were compared using one-way analysis of variance (ANOVA). The Kruskal-Wallis test was used for ARI scores and pairwise comparisons were done using the Mann-Whitney U test with Bonferroni correction. Results: Mean SBS values (MPa) and standard deviations for the groups were: group 1, 13.18 ± 3.45; group 2, 13.52 ± 4.38; group 3, 10.33 ± 4.74; group 4, 13.00 ± 3.47; and group 5, 12.46 ± 6.31. No significant differences were observed in the SBS of all the groups evaluated, but there was a significant difference in ARI scores, with group 3 showing higher ARI scores than groups 1 and 4. Conclusions: Er:YAG laser ablation and self-etching primer application showed similar SBS values as conventional acidetching for bonding brackets.

Free first page

This paper was cited by:

Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium–aluminum–garnet laser and bur
Yonca Korkmaz, Emre Ozel, Nuray Attar, Ceren Ozge Bicer, Erhan Firatli
Lasers in Medical Science. May 2009
CrossRef
Microleakage of Class V Cavities with Different Adhesive Systems Prepared by a Diamond Instrument and Different Parameters of Er:YAG Laser Irradiation
Nuray Attar, Yonca Korkmaz, Emre Ozel, Ceren Ozge Bicer, Erhan Firatli
Photomedicine and Laser Surgery. Dec 2008, Vol. 26, No. 6: 585-591
Abstract | Full Text PDF | Reprints & Permissions
All articles